Water supply & fire-flow intelligence

Know your water supply. Prove your fire flow.

WaterDash turns every NFPA 291 flow test into an answer: is the available fire flow at an address enough for the needed fire flow the building requires? Get a defensible number in seconds — and a verifiable certificate insurers and AHJs accept. Built by the team behind FireDash.

NFPA 291 · AWWA M17 · ISO Pay per report No subscription to start
Fire-flow availability 1428 Maple Ave
PASS
Adequate · Class A
1,750 gpm available · 1,500 gpm needed
Available @ 20 psi 1,750 gpm
Needed fire flow 1,500 gpm
Margin +250 gpm
Governing hydrant 220 ft · Class A
How it works

From an address to a defensible answer — in minutes.

WaterDash standardizes fire-flow analysis so a utility, an engineer, or an AHJ can produce a defensible water-supply adequacy result without chasing data across spreadsheets and reference tables.

1. Enter a property

Give an address (or drop a pin) plus construction class and area. WaterDash finds the nearest gauged hydrants automatically.

2. Compute the flow

Available fire flow (projected to 20 psi) versus needed fire flow (ISO NFF) — with the governing hydrants and the math shown.

3. Issue the certificate

Turn a passing result into a verifiable WD- certificate — pay-per-report, checkable at verify.firedash.us.

Why WaterDash

Everything you need to assess, document, and prove a water supply.

Stop juggling pitot readings, pressure logs, and ISO tables. WaterDash brings the whole fire-flow workflow into one place.

Available fire flow

Project any NFPA 291 / AWWA M17 flow test to a 20 psi residual to get the gallons-per-minute actually available at an address.

Needed fire flow

Compute ISO needed fire flow (NFF = 18·C·√A) — or the IFC Appendix B table — from construction class and effective area.

Verifiable certificates

Issue a Water Supply Adequacy Certificate (WD-) any insurer or AHJ can confirm at verify.firedash.us.

Distribution network map

See hydrants as flow & pressure nodes, color-coded by AWWA class, with low-pressure zones and weak spots surfaced.

Flow-test scheduler

Log NFPA 291 tests, auto-rate each hydrant, and track the AWWA test cycle so nothing falls overdue.

One data layer

Built on the same authoritative hydrant + property data that powers FireDash and RiskDash.

The engine

Standards-grade, every number traceable.

No black box. Available flow, needed flow, and the flow class all trace to a published method and a real field measurement.

Available @ 20 psi
Q₂₀ = Qᶠ · ((Hₛ − 20) / (Hₛ − Hᵣ))0.54 — NFPA 291 / AWWA M17.
Needed fire flow
ISO NFF = 18 · C · √A by construction class & effective area (or IFC Appendix B).
AWWA flow class
AA ≥1500 · A 1000–1499 · B 500–999 · C <500 gpm, color-coded on the map.
NFPA 291 flow tests
Log static, residual, and test flow; WaterDash rates the hydrant and schedules the next test.
Weak-spot alerts
Surface Class C hydrants, low-pressure zones, and overdue tests across the district.
Hydrant proximity
Governing hydrant distance feeds both the result and the FireDash insurance-distance story.
The sellable artifact

A Water Supply Adequacy Certificate anyone can verify.

A passing fire-flow result becomes a WD- certificate — carrying a certificate number, a tamper-evidence hash, and a QR code. An insurer or AHJ confirms it is genuine and unaltered at verify.firedash.us. Pay-per-report; no subscription required.

Generate a certificate

WD-2026-04417

Authentic
Property
1428 Maple Ave
Result
PASS · +250 gpm
Available
1,750 gpm · Class A
Needed
1,500 gpm
Verify at verify.firedash.us · hash a9f3c1…4d61
By the numbers

Backed by the broader FireDash platform.

The same authoritative hydrant + agency data that powers FireDash and RiskDash feeds every WaterDash result.

0
NFPA standard
0
psi residual basis
0
AWWA flow classes
0
Fire departments connected
FAQ

Questions, answered.

Water utilities managing a distribution network, fire-protection engineers and sprinkler designers sizing supply, AHJs and plan reviewers, and insurers underwriting on available fire flow. The same accounts work across the FireDash platform.

WaterDash projects a measured NFPA 291 / AWWA M17 flow test to a 20 psi residual using the standard rated-capacity formula (the 0.54 exponent). Needed fire flow uses the ISO formula NFF = 18 · C · √A (or the IFC Appendix B table). Every number on a result traces back to a published method and a real field measurement.

A verifiable PDF (a WD- certificate) that records the available vs. needed fire flow, the governing hydrants, and the result. It carries a certificate number, a tamper-evidence hash, and a QR code that anyone can check at verify.firedash.us to confirm it is genuine and unaltered. Issuing one is a one-time pay-per-report fee — no subscription required.

They share one data layer. FireDash is the fire department’s view of the hydrant network; RiskDash is the insurer/property-risk view; WaterDash is the water-utility / water-supply view. Same hydrants, same identity, different focus.

No. Checking fire-flow availability is free, and issuing a certificate is pay-per-report. A subscription adds the utility tools — the distribution map, flow-test scheduler, and multi-property management.

Check your first property today.

Create a free account and run a fire-flow availability check in under five minutes. Pay only when you issue a certificate.

Get started — free